    Introduce

    System 1 (SCH 01)Standard solar system , 1 tank System 2 (SCH 02): 1 tank + 3-ways valve layer heating System 3 (SCH 03): 2 tanks+ circuit pump control logic System 4 (SCH 04): 2 tanks+ heat transferring control logic System 5 (SCH 05): 2 tanks+ valve control logic System 6 (SCH 06): east-west collectors + 1 tank System 7 (SCH 07): east-west collectors + 1 tank +valve control logic System 8 (SCH 08): east-west collectors + 2 tanks +valve control logic System 9 (SCH 09): east-west collectors + 2 tanks +valve control logic System 10 (SCH 10): 3 tanks + pump control logic System 11 (SCH 11): east-west collector+3 tanks +pump+valve control logic System 12 (SCH 12): 3 tanks +valve control logic System 13 (SCH 13): east-west collector+ 3 tanks +valve control logic System 14 (SCH 14): 1 tanks + swimming pool+ valve + heat exchanger control logic System 15 (SCH 15)east-west collector +1 tanks + swimming pool+ valve + heat exchanger control logic System 16(SCH 16)east-west collector +1 tanks + swimming pool+ valve + heat exchanger control logic System 17(SCH 17): 1 tanks + heating return control logic System 18(SCH 18): east-west collector + heating return control logic System 19(SCH 19): east-west collector +valve + heating return control logic System 20(SCH 20): standard solar system, heat exchanger control logic System 21(SCH 21): 2 tanks + heat exchanger control logic System 22(SCH 22): east-west collector + heat exchanger control logic System 23(SCH 23): east-west collector +2 tanks + heat exchanger control logic System 24(SCH 24): east-west collector + valve + heat exchanger control logic System 25(SCH 25): east-west collector + valve + 2 tanks + heat exchanger control logic System 26(SCH 26): 2 tanks + valve + heating return control logic System 27(SCH 27): east-west collector +2 tanks + valve + heating return control logic System 28(SCH 28)east-west collector +2 tanks + valve + heating return control logic System 29(SCH 29): 1 tank+ valve layer heat + heating return control logic System 30(SCH 30): east-west collector+ valve layer heat + heating return control logic System 31(SCH 31): 2 tanks + heat transferring + heating return control logic System 32(SCH 32): 1 tank + heat exchanger + heating return control logic System 33(SCH 33): east-west collector +2 tanks + valve + heat exchanger control logic System 34(SCH 34): 2 tanks + valve + heat exchanger control logic System 35(SCH 35): 2 tanks + heat exchanger+ heat transferring control logic System 36(SCH 36): 2 tanks + valve+ heat transferring control logic System 37(SCH 37): east-west collector + 2 tanks + heat transferring control logic System 38(SCH 38): east-west collector + 2 tanks + valve + heat transferring control logic System 39(SCH 39): east-west collector + 2 tanks + valve control logic

    Main technical data
    Technical data
    Specification Parameter
    Appearance of controller 200mm×155mm×45mm
    Power supply AC230V±10%
    Power consumption3W
    Accuracy of temperature measuring ±2oC
    Range of collector sensor measuring -10~220oC
    Range of tank sensor measuring 0~100oC
    Suitable power of pump 9200W
    Suitable power of electrical heater 11500W
    Inputs 2 x Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
    10 x NTC10K, B3950 sensor (135oC) for tank or pipe, (PVC cable105oC),
    Outputs 9 relays for circulation pumps or 3-way electromagnetic valve
    1 relay for electrical heater
    Ambient temperature -10~50 oC
    Water proof grade IP40
    Main functions
    4.3 Main menu - THET timing heating
    4.4 Main menu - DT Temperature difference
    4.5 Main menu - TEMP Temperature
    4.5.1 EMOF Collector emergency shutdown function activated
    4.5.2 EMON Collector emergency shutdown function exit
    4.5.3 CMX Maximum limited collector temperature (collector cooling function)
    4.5.4 CMN low temperature protection of collector
    4.5.5 CFR frost protection of collector
    4.5.6 REC Tank re-cooling function
    4.5.7 SMX1 Maximum temperature of tank 1
    4.5.8 SMX2 Maximum temperature of tank 2
    4.5.9 SMX3 Maximum temperature of tank 3
    4.5.10 MAX1 Maximum switch-off temperature (for heat transferring between tank and heating loop)
    4.5.11 MIN1 Minimum switch-on temperature (for heat transferring between tank and heating loop)
    4.5.12 MAX2 Maximum switch-off temperature (for heat transferring between tank and heat exchanger)
    4.5.13 MIN2 Minimum switch-on temperature (for heat transferring between tank and heat exchanger)
    4.6 Main Menu - FUN Auxiliary function
    4.6.1 DVWG Anti legionnaires' function
    4.6.2 CIRC Temperature controlled hot water circ