0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System

Categories Fire Resistant Cable
Brand Name: Shenzhen Chengtiantai
Model Number: YTTW
Certification: CCC
Place of Origin: Guangdong,China(Mainland)
MOQ: 100 units
Price: on request
Payment Terms: L/C, T/T
Supply Ability: 50,000 m/day
Delivery Time: 7 / 15 working days
Packaging Details: steel wooden drum
Rate Voltage: 0.6/1 KV
Conductor: Bare copper class 2
Light Duty: 500 V
Insulation: mica tape
Heavy Duty: 750 V
Sheath: Copper metallic sheath
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    0.6/1 KV Fire Resistant Electrical Wire , Fire Rated Cable For Fire Alarm System


    Fire resistance cable YTTW


    YTTW cable is designed for aboveground applications.


    Engineered to replace conduit and wire applications, this all-in-one cable assembly offers fewer installation steps.


    The copper metallic sheath protects the conductors from damage before,during and after installation and provides overall flexibility not available with a conduit.



    — Flame Retardant
    — High Operating Temperatures

    LSOH Halogen-free
    Great Mechanical Strength
    Competitive Installed Cost
    Public Places

    Our YTTW cables provide outstanding electrical and fire-proof properties, and are halogen free.


    The design, construction and testing are compliant with international standard IEC60502 and testing standard EN 50200 (PH-90),with standing temperatures of 840 °C for 90 minutes, which means they are capable of remaining in working order despite the most extreme fire conditions. Hence they are known as FIRE RESISTANT cables.


    This type of cable is made up of single and multi-cores 600/1000V cables Service Temperature 90°C Emergency Overload Temperature 105°C Short-Circuit Temperature 250°C


    Installation of these cables is essential in safety circuits (detection and alarm circuits,evacuation and fire-fighting systems).


    STANDARDS:
    NationalInternational
    ConstructionGB/T 12706IEC 60502
    Non fire-propagatingGB/T 18380.3IEC 60332-3
    Low opacity of smoke emittedGB/T 17651.2IEC 61034-2
    Fire-resistantGB/T 12666.6IEC 60331
    Low acidity and corrosiveness of gasesGB/T 17650.2IEC 60754-2
    Halogen freeGB/T 17650.2IEC 60754-1
    Non flame-propagatingGB/T 18380.1IEC 60332-1-2

    Rated working voltage:


    –​ Light Duty: 500 V

    –​ Testing Voltage (50 Hz): 2500 V - 15 min


    –​ Heavy Duty: 750 V

    –​ Testing Voltage (50 Hz): 2000 V - 15 min


    Cable structure
    ConductorStranded copper conductor class 2
    Insulationmica tape1, flame retardant
    FillerGlass yarns
    core wrapingCore wrapping with glass-fibre tape as flame-protection
    SheathCorrugated Copper
    Outer covering (Optional)Anticorrosion Outer Sheath PVC

    USAGE CHARACTERISTICS
    Service Temperature90°C
    Emergency Overload Temperature105°C
    Short-Circuit Temperature250°C
    Laying Temperatureshould not be lower than 0°C
    Minimum bending radius when layingSingle core: r = 6 x cable outer diameter
    Sheath colourThe standard color is orange, other colors are available.

    SINGLE CONDUCTOR

    Nominal

    cross

    Section

    Nominal insulation thickness

    Thickness of

    metallic

    sheath

    Outer

    Diameter

    approx.

    current

    carrying

    capacity

    Voltage

    drop
    cos μ= 0,8

    mm2mmmmmmAV/A.km
    1×1.00.800.403.53-23.10
    1×1.50.800.403.783215.40
    1×2.50.800.404.18429.48
    1×4.00.800.504.85565.90
    1×6.00.800.505.36703.90
    1×101.000.507.02972.33
    1×161.000.608.241251.47
    1×251.000.609.561650.92
    1×351.000.6010.702000.67
    1×501.200.7012.602450.49
    1×701.200.7014.403050.34
    1×951.200.8016.503750.25
    1×1201.200.8018.144350.20
    1×1501.400.8020.155000.16
    1×1851.400.9022.105800.13
    1×2401.400.9024.856850.10
    1×3001.601.0027.707950.08
    1×4001.601.0030.409300.06

    2 CONDUCTOR


    Nominal

    cross

    Section

    Nominal Insulation thickness

    Thickness of

    metallic

    sheath

    Outer

    Diameter

    approx.

    Ampacity

    Voltage

    drop
    cos μ= 0,8

    mm2mmmmmmAV/A.km
    2×2.50.800.506.963318.96
    2×4.00.800.608.104411.8
    2×6.00.800.609.12577.8
    2×101.000.7012.44784.66
    2×161.000.7014.481042.86
    2×251.000.8017.321352.52
    2×351.100.8019.901682.24
    2×501.200.9023.002041.64
    2×701.201.0026.802631.42
    2×951.201.0030.603201.08
    2×1201.201.0033.883730.98

    THREE CONDUCTOR


    Nominal
    cross
    Section

    Nominal insulation thicknessThickness of

    metallic

    sheath

    Outer

    Diameter

    approx.

    Ampacity

    Voltage

    drop
    cos μ= 0,8

    mm2mmmmmmAV/A.km
    3×2.50.80.607.562916.4
    3×4.00.80.608.573810.2
    3×6.00.80.609.67466.74
    3×101.00.7013.22654.03
    3×161.00.7015.42852.54
    3×251.00.8018.461181.59
    3×351.10.8021.431501.16
    3×501.20.9024.551920.85
    3×701.21.0028.632280.59
    3×951.21.0032.722730.43
    3×1201.21.0036.263140.35

    FOUR CONDUCTOR


    Nominal
    cross
    Section
    Nominal insulation thicknessThickness of

    metallic

    sheath

    Outer

    Diameter

    approx.

    AmpacityVoltage

    drop
    cos μ= 0,8

    mm2MmmmmmAV/A.km
    4×6.00.80.6010.59466.74
    4×101.00.7014.52654.03
    4×161.00.8017.18852.54
    4×251.00.9020.571181.59
    4×351.11.0023.861501.16
    4×501.21.0027.341920.85
    4×701.21.0031.692280.59
    4×951.21.0036.272730.43

    3+1 CORE
    Nominal
    cross
    Section
    Nominal insulation thicknessThickness of

    metallic

    sheath

    Outer

    Diameter

    approx.

    AmpacityVoltage

    drop
    cos μ= 0,8

    mm2mmmmmmAV/A.km
    3×16+1×101.00.8016.56852.54
    3×25+1×161.00.9019.771181.59
    3×35+1×161.11.0022.181501.16
    3×50+1×251.21.0025.871920.85
    3×70+1×351.21.0029.812280.59
    3×90+1×501.21.0034.042730.43

    Notes:


    Ampacities based on 90°C conductor temperature and 40°C ambient temperature according to IEC 287 standard


    The voltage drop based on conductor temperature 90°C is on the high side calculated only for reference


    When the cable adopt compressed cores, diameter of cable should be 95% of normal diameter, diameter of metallic sheath should be adjusted correspondingly. When enhancing the insulation, outer diameter of cable is increased for about 5%.


    1 Glass cloth reinforced Muscovite mica tape

    2 Current ratings in Ampere (A) up to 30° C ambient temperature