Brand Name: Fanke High-Voltage
Model Number: UT 575A
Certification: ISO9001
Place of Origin: China
MOQ: One unit
Price: Negotiable
Payment Terms: T/T
Supply Ability: 10units/month
Delivery Time: 10 work days
Packaging Details: Export standard wooden case with fumigation free
Usage: Grounding Resistance Test , Soil Resistivity Test , DC Resistance Test
Test method: 2/3/4-wire measurements
Measurement range: Ground Resistance range0.01Ω~30.00kΩ
Feature: With double clamp test, Large-diameter current clamp design
Diameter of current clamp: 50mm
Meet standard: IEC60101-1; IEC61010-2-31; IEC61557-1,5
name: soil resistivity testing equipment
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester

    Double Clamp Multi-function Grounding Resistance Tester , Soil Resistivity Tester , DC Resistance Tester

    I. Product Introduction :

    The UT575A grounding resistance tester is microprocessor controlled to accurately detect ground resistance, soil resistivity, ground voltage, DC resistance and AC current. The same screen shows the resistance value of the auxiliary electrode, which is convenient for judging the measurement error caused by environmental factors, and it is convenient to measure the true resistance value of the grounding resistance more accurately. At the same time, 500 sets of data can be stored, and the monitoring software can monitor the data online. The USB data is uploaded to the PC and has unique functions such as numerical maintenance and intelligent alarm prompts.
    The measurement usage of the tester inludes as following:

    1. 2/3/4-pole measurement Ground Resistance, Ground Resistance range0.01Ω~30.00kΩ

    2. Selection method, double clamp method to measure the grounding resistance

    3. Soil Resistivity 0.01Ωm~9999kΩm

    4. Ground Voltage 0.1V~100.0V

    5. AC current leakage current measurement 0.01mA~1000A


    II. Main Features

    1. Large-diameter current clamp design for measuring any grounding resistance of complex grounding conditions such as single point and mesh grounding;
    2. Precision 4-wire method, 3-wire method and simple 2-line method, selection method, double-clamp method measurement;
    3. Fast filtering technology, with excellent anti-interference ability and environmental adaptability, repeated test consistency, ensuring measurement accuracy, stability and reliability.
    4. Data storage function for 500 sets of data storage;
    5. Upload to PC via USB data cable for display analysis and output test report

    III. Main Technical Data


    Measurement functionsMeasurement rangeAccuracyResolution
    2/3/4-wire methods for grounding resistance measurement(Re)0.00Ω~29.99Ω±2%rdg±5dgt0.01Ω
    30.0Ω~299.9Ω±2%edg±3dgt0.1Ω
    300Ω~2999Ω
    3.00kΩ~30.00kΩ10Ω
    DC resistance(R-)0.00Ω~299.9Ω±2%edg±3dgt0.1Ω
    300Ω~2999Ω
    3.00kΩ~30.00kΩ10Ω
    Selection method for grounding resistance measurement(Re)0.00Ω~29.99Ω±2%rdg±5dgt0.01Ω
    30.0Ω~299.9Ω±2%edg±3dgt0.1Ω
    300Ω~3000Ω
    Double clamp method for grounding resistance measurement(Re)0.01Ω~0.99Ω±10%rdg±10dgt0.01Ω
    1.0Ω~9.9Ω0.1Ω
    10Ω~100Ω
    Soil Resistivity(ρ)0.00Ωm~99.99Ωmρ=2πaR0.01Ωm
    100.0Ωm~999.9Ωm0.1Ωm
    1000Ωm~9999Ωm1Ωm
    10.00kΩm~99.99kΩm10Ωm
    100.0kΩm~999.9kΩm100Ωm
    1000kΩm~9999kΩm1kΩm
    Grounding voltage0.00~100.0V±2%rdg±3dgt0.01V
    AC Current0.0mA~1000A±2%rdg±3dgt0.1mA
    Basic functions
    Measurement methodPrecision 4-wire method, 3-wire method and simple 2-line method, selection method, double-clamp method measurement for grounding resistance
    Display mode4-digit LCD display
    Data storage500 groups
    Data communicationUSB interface
    Measurement time2time/second
    Overload display
    Overload protection
    Alarm functions
    Auto shut-down
    Under-voltage indication
    Backlight function
    Power supplyDC 6V 4.5ah lead-acid battery Continuous standby for more than 100 hours
    Safety levelCAT III 300V
    Standard accessories4pcs of grounding probes, 2pcs of current clamps , 1 software disk, 1 communication cable, 4pcs of testing wires, 2pcs of simple testing wires, 1charger 1 6v battery ,1 manual and quality certificate, 1 storage bag