Type: | HVAC Systems |
Voltage: | AC230V |
Current load: | 16A floor heating thermostat |
Setting range: | +5~+90℃ floor heating thermostat |
Floor sensor: | Rubber-thermoplastic NTC sensor |
Housing material: | Self-extinguishing PC |
Company Info. |
Nanjing Saiko Controls Co.Ltd |
View Contact Details |
Product List |
Digital Weekly Programming Heated Floor thermostat With Floor Sensor
Introduction
SK51 Weekly circulation digital programming thermostat with LCD screen , which has 6-event everyday . Manual mode and programme mode could be selected .The thermostat is recommended for control of electric heating devices or on/off valve actuator use in hydronic floor heating .
electric floor heating thermostat
digital thermostat
room heating thermostat
electronic heating thermostat
thermostat control
electric floor heating thermostat( digital thermostat, room heating thermostat, electronic heating thermostat, thermostat controller)
Technical data
Power Supply | AC200-240VAC 50/60HZ |
Accuracy | ±0.5ºC |
Probe sensor | NTC |
Power Consumption | <0.3W |
Load current | 3A(water heating),16A(electric heating) |
Temperature Adjustable Range | 5°C~90°C( can adjust to 35°C~90°C) |
Limit Temperature Range | 5°C~60°C( factory setting: 35°C) |
Output | Switch relay |
Insulating condition | Normal environment |
Running program | Set per 1 week as a cycle |
Installation | Wall mounted |
Application | Water Floor Heating System |
Electric Floor Heating System | |
Infrared Heater System | |
Certificate | CE,RoHS |
Sensor Failure:
E0:Built-in sensor short-circuited or disconnected
E1:Exernal sensor short-circuited or desconnected.
When shows E0/E1 error, thermostat must be checked till the error is eliminated