Sign In | Join Free | My enlightcorp.com
enlightcorp.com
Products
Search by Category
Home > Air Conditioners >

50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel

Categories Air Handling Units
Brand Name: EuroKlimat
Model Number: EKDM
Certification: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Place of Origin: China
MOQ: 1
Price: negotiation
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
Delivery Time: 15 working days after received your payment
Packaging Details: Plywood
Product Name: Fresh air handling units with heat recovery wheel
Installation: Ceiling/floor installation
Cooling Capacity(kW): 25-300
Heating Capacity(kW): 28-330
Air Flow(m3/h): 5000-60000
Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa): 3.3
Coils rows: 4/6
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat Recovery Wheel

EK keeps looking for valuable distributors and partners around international markets…


50 mm PU insulation double skin modular fresh air handling units with heat recovery wheel


EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.


• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.


• Internal panels are made of steel plates galvanized with aluminum and zinc, with an assured service life of more than 15 years. All panels feature end-to-end joints and smooth surfaces, without any bur or corroded point.


• The internal panels feature reinforced design, which is strong enough to support the largest air handling unit.


• The unit panel has two thicknesses, namely 30mm and 50mm.Inside the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.


• Each functional section of the unit is equipped with a steel trough base, thus ensuring it is well supported, easy to transport and assemble. The overall robustness of the unit meets the standard of CEN2.


Heat Recovery Section


The wheel heat recovery is molded using customized alveolate metal template and coated with special desiccant adsorbing material. In typical installations, the wheel is fixed in the middle of the pipe and divided into two half-moons, pumping stagnant indoor air out of one half-moon, and fresh air into the other. Meanwhile, the wheel revolves slowly (approximately 20RPM) to transfer sensible/latent heat from one half-moon to the other through its metal plates and desiccant absorbing material (heat liberation), condensing vapor from high-humidity side and releasing vapor into low-humidity side by evaporation and heat absorption.


Speedm/s1.522.533.544.555.5Height and Width A mmFlow depth W mm
FPM30040050060070080090010001100
efficiencyHeating878481797876747270
Cooling878481797775737169
Pressure
drop
Pa7494114142170201239267300
In.w.c.0.290.370.450.560.670.790.941.051.18
HRW500m3/h4095466827659551092122813651501700365
HRW600m3/h6238311039118914541662187020782286800365
HRW700m3/h87911721465169920512345263829313224850365
HRW800m3/h117715691962237927463039353139324316950365
HRW900m3/h1517202225283059353940444550505555611030365
HRW1000m3/h1898253131643738442950625695632769601130365
HRW1100m3/h2322309638694588541761916965773985131230365
HRW1200m3/h27303640455054386371728181919101100111330365
HRW1300m3/h315742105262628773678419947210524115761430365
HRW1400m3/h3701493461687307863598691110312336135701530365
HRW1500m3/h428657157144866610002114301285914288157171630365
HRW1600m3/h485964798099968611338129581457716197178171730395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Specifciations


Model
EKDM
Rated air flow m3/hWindward area of coil (m2)Air flow (m3/h)Diameter of fan impeller mmFan performance
2.252.502.753.00Max. total pressure of fan PaMax. motor power kW
m/sm/sm/sm/s
30620000.23186320702277248416013002.2
40630000.34275430603366367220013003
40740000.41332136904059442822515003
40850000.48388843204752518425018005.5
50860000.65526558506435702028018007.5
60770000.69558962106831745228018007.5
60880000.81656172908019874831518007.5
51190000.9476148460930610152315180011
610100001.05850594501039511340355200011
611120001.179477105301158312636400200015
712150001.5512555139501534516740450200015
812180001.8114661162901791919548500200018.5
813200001.9816038178201960221384500200018.5
915250002.6621546239402633428728560200022
1015300002.9924219269102960132292630200030
1313350003.4027540306003366036720630200030
1315400003.9932319359103950143092710200030
1515450004.6537665418504603550220800200037
1417500004.9540095445504900553460800200045
1520600006.3651516572406296468688900200045
1720700007.2758887654307197378516900200055
1722800008.05652057245079695869401000200075
1626900009.01729818109089199973081000200075
182610000010.21827019189010107911026811202000110
1852200000020.421654021837802021582205361120x22000110x2
3652400000040.843308043675604043164410721120x42000110x4

Note:
■ This table only lists some typical models among many models for quick model selection.
■ Total fan pressures listed above are tested on standard fans with rated air flow.
■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units.