Sign In | Join Free | My enlightcorp.com
enlightcorp.com
Products
Search by Category
Home > Motors >

Support optional LCD keypad you will know all parameters meaning no need user manual

Categories MPPT VFD Solar Pump Inverter
Brand Name: VEIKONG
Model Number: VFD500-PV
Certification: CE
Place of Origin: China
MOQ: 5
Price: Negotiable
Payment Terms: L/C, T/T, Western Union
Supply Ability: 15000pcs per Month
Delivery Time: depend on the order quantity
Packaging Details: the power less than 45kw use Carton, starting from 45kw use Wooden case
Product Name: solar pump inverter
Voltage: 220v/380v
frequency: 50hz/60hz
Display: LED+LCD
Protection: ip20 and ip65
Color: White and blue
Remote control: GPRS support
Original: China
MPPT efficiency: 99.9999%
Brand: VEIKONG
Special function: MPPT and PID
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Support optional LCD keypad you will know all parameters meaning no need user manual

2.2KW 4KW GPRS Pump Inverter Solar VFD For Solar Irrigation System


2.2KW 4KW Solar Pump Inverter GPRS Solar VFD For Pump Solar Irrigation System


VEIKONG IS Solar Ac Pump Controller chinese manufacturer

Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)
Features:
  1. Support Hybrid solar power and ac power at same time
  2. Support optional LCD keypad, you will know all parameters meaning , no need user manual
  3. Support optional GPRS module to remote control and monitor solar pumping situation
  4. Support optional output reactor to protect the motor
  5. Support water full, dry running, wake and sleep protection functions.


Electrical Specifications


PV input
Maxiumum input DC voltage400V DC
Recommended MPPT voltage range250~350V DC
Recommended input Operation Voltage310V DC
Grid or backup generator input
Input voltageSingle phase 220V(-15%~30%)
Output Specification
Rated output voltage3PH 220V
Output frequency0~500.00Hz (default: 0~50.00Hz)
380V Solar Pumping Inverter
Input Specification
PV input
Maxiumum input DC voltage800V DC
Recommended MPPT voltage range450~650V DC
Recommended input Operation voltage540V DC
Grid or backup generator input
Input voltageThree phase 380V(-15%~30%)
Output specification
Rated ouput voltage3PH 380V
Output frequency0~500.00Hz (default: 0~50.00Hz)
Protection
Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.


Accessories:


1. GPRS (support 2g/3g/4g internet)


2. Output reactor


3. LCD keypad








Model Range

Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
VFD500M-20T00150-PV220V80071.5SIZE A
VFD500M-20T00220-PV220V80010.62.2SIZE A
VFD500M-40T00150-PV380V8004.21.5SIZE A
VFD500M-40T00220-PV380V80062.2SIZE A
VFD500-20T00150-PV220V80071.5SIZE A
VFD500-20T00220-PV220V80010.62.2SIZE A
VFD500-20T00400-PV220V800174SIZE A
VFD500-40T00150-PV380V8004.21.5SIZE A
VFD500-40T00220-PV380V80062.2SIZE A
VFD500-40T00400-PV380V8009.44SIZE A
VFD500-40T00550-PV380V800135.5SIZE B
VFD500-40T00750-PV380V800177.5SIZE B
VFD500-40T01100-PV380V8002511SIZE C
VFD500-40T01500-PV380V8003215SIZE C
VFD500-40T01850-PV380V8003818.5SIZE D
VFD500-40T02200-PV380V8004622SIZE D
VFD500-40T03000-PV380V8006030SIZE E
VFD500-40T03700-PV380V8007537SIZE E
VFD500-40T04500-PV380V8009645SIZE F
VFD500-40T05500-PV380V80011255SIZE F
VFD500-40T07500-PV380V80015075SIZE G
VFD500-40T09000-PV380V80017690SIZE G
VFD500-40T11000-PV380V800210110SIZE H
VFD500-40T13200-PV380V800253132SIZE I
VFD500-40T16000-PV380V800304160SIZE I
VFD500-40T18500-PV380V800340185SIZE J
VFD500-40T20000-PV380V800377200SIZE J

Trial run(How to start solar pump inverter)
Make sure all cables connections of solar panel and pump motor correct and no
need to set any parameter, if you want to set parameter, you can do as follows.
Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per motor pump name
plate If dry run protection is required, measure the unload protection current(see details in
user manual chapter for dry run function) If dry run protection not required then miss this step
and go to step 2.
Step 2: Set other related special solar pump parameters for optimization if needed.
Step 3: After trial run finishing, if motor pump still not output water when inverter is running
more than 40 Hz. Please disconnect the power supply and replace any two-phase wiring of
the motor

Technical Questions and solutions

1. How to achieve Automatic start after stop?
If it is controlled by keyboard, so there is no need to set any parameter(P47.03 waiting time)If you want to
control by external switch. First set P00.06=1 and use a wire or switch to connect com and DI1,When the
switch is closed, the drive run, when the switch is open, the drive stop
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
143.Use level probe in the well for protection against dry running
1 st solution: See self learning of dry run(For LED display)
2 nd solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
3 rd solution: If your sensor is digital switch, just short D4 and com
4 th solution: If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and
P41.03-P41.06

Buy Support optional LCD keypad you will know all parameters meaning no need user manual at wholesale prices
Send your message to this supplier
 
*From:
*To: Shenzhen Veikong Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0