Sign In | Join Free | My enlightcorp.com
enlightcorp.com
Products
Search by Category
Home > Other Drive & Storage Devices >

High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom

Categories Air Filter Hepa Box
Brand Name: GCC
Certification: ISO9001,ISO14001,ISO45001,CE
Place of Origin: China
MOQ: 1
Price: 135$
Payment Terms: T/T
Supply Ability: Manufacturer
Delivery Time: 10-14
Packaging Details: Wooden Box
Filtration Efficiency: 99%
Size: 39*41*32CM
Keyword: Cleanroom Air Outlet
Material: Stailess Steel SUS304/201/Q195 /galvanized Sheet
Warranty: 1 year
Package Contents: 1 Air Filter Outlet
Application: Cleanroom
Color: White
Condition: New
Function: Air Purification
Weight: 34KG
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Efficiency Filter Outlet HEPA Box With Smooth Diffuser Plate For Pharmaceutical Cleanroom

The Seal HEPA Box for Pharmaceutical Cleanroom is made of high-quality cold-rolled steel plate. The surface is electrostatically sprayed,including static pressure tank, high-efficiency filter, diffuser plate, and a new level of clean room. It is used as a filter to clean the ceiling with less investment and simple construction. In order to ventilate the high-efficiency filter after obtaining the ideal static pressure, the high-efficiency filter is properly used. Compact structure, reliable performance, strong ventilation, easy installation and easy maintenance.
We are dust free design and manufacturer specialist, we have a R&D department,and have our own factory, also we have some long-time cooperated suppliers. For the whole dust free project, from design until the dust free plant installation,we will do one-stop service for you,and we will keep lifetime after sales service for your dust free project, all products for dust free we are provide for you, as clean room, air shower room, pass box, ect.

Application:
The terminal air filtration equipment used for the newly-purified 1000-, 10,000-, 100,000-class and clean room purification projects meets the requirements of purification requirements, and can be widely used in the purification of air-conditioning systems in the pharmaceutical, sanitary, electronics, and chemical industries.


Core Advantages:

1.The surface of the box is treated with electrostatic spray.
2.The tank seal design further enhances its uniqueness
3.Strong corrosion resistance
Material: color steel plate or galvanized sheet spray.
Tips:can be customized according to requirements


Main Technical Parameter:

ProductAir Diffuser With Net Air Supply Unit Outlet Air Hepa Filter Box
TechnologyPurification Engineering
Body install Size370*370*370;534*534*370;660*660*370,965*625*370;1270*660*370mm
Outlet top size434*434*370;588*588*370;744*744*370;1334*724*370;1374*744*370mm
Frame MaterialSUS Aluminum/Stainless Steel
Rated Air Flow500;1000;1500;2000;3000m3/h
TypeStainless Steel Work Surface,PMMA enclosure,can be equipped with ultraviolet lamp
remote control electrical interface.
FrameStainless Steel
HS CODE8421399090
Filter efficiency99.99%@0.3um
ColorIvory white

FAQ:

1. What is the function of a high-efficiency air supply outlet?

High-efficiency air supply outlets are critical components of cleanroom ventilation systems, equipped with HEPA or ULPA filters.
They are designed to:
* Filter airborne particles (≥99.97% efficiency for particles ≥0.3μm)
* Distribute clean air uniformly (maintaining unidirectional or mixed airflow)
* Control pressure differential and air exchange rates (ensuring ISO cleanliness standards)
2. How often should the filters in high-efficiency air supply outlets be replaced?
Replacement intervals depend on the operating environment. General recommendations:
* Pre-filters: Inspect/replace every 3-6 months
* HEPA filters: Replace every 2-5 years (or when pressure drop alarms trigger)
Key influencing factors:
✔ Air pollution levels (e.g., pathogen-containing aerosols in pathology labs may require shorter cycles)
✔ Operational hours (24/7 use demands more frequent maintenance)
✔ Pressure differential data (replace when ΔP ≥ 1.5× initial value)
3. How to determine if a high-efficiency air supply outlet has failed?
Testing methods:
* Pressure monitoring: Significant drop in ΔP across the outlet (indicating possible damage)
* Particle counting: Downstream particle counts exceeding standards (e.g., >3,520 particles/m³ for ≥0.5μm in ISO Class 5)
* DOP/PAO leak testing: Scan filter edges and media; >0.01% leakage rate indicates failure