Brand Name: Rosemount
Model Number: 3144
Place of Origin: China
MOQ: 1 pc
Price: USD 600 1 pc
Payment Terms: T/T
Supply Ability: 100 pc 1 week
Delivery Time: 7-14 days
Reference Accuracy: Standard: 0.05% Platinum: up to 0.025%
Measuring Medium: Pressure, Level and Flow
Measuring Principle: Absolute and gauge pressure
Wetted Parts Material: 316L Stainless Steel
Approvals: ATEX, IECEx, FM, CSA
Pressure Sensing Element: Piezoresistive
Output Signal: 4-20 mA
Turndown Ratio: 100:1
Certifications: ATEX, IECEx, FM, CSA
Protocol: HART/RS485
Ingress Protection: IP67
Process Connection: 1/2" NPT
Mounting Method: DIN rail or wall mount
Weight: 0.5 kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

3144P Harsh Environment 4-20mA Output HART Protocol transmitter Temperature Transmitter

3144P Harsh Environment 4-20mA Output HART Protocol transmitter Temperature Transmitter



Highlights — Features & Functions

Advanced Sensing & Accuracy

  • Universal inputs: Accepts RTDs (2/3/4-wire), thermocouples (Types B, E, J, K, N, R, S, T, L, U, W5Re/W26Re), millivolt, and ohm signals
  • Single or dual‑sensor mode: Supports differential, averaging, redundant measurement, Hot‑Backup®, and Sensor Drift Alert capabilities
  • Transmitter‑Sensor Matching (C2 option): Calibrates with RTD sensor characteristics to reduce interchangeability error by ~75%

Diagnostics & Safety

  • Thermocouple loop degradation detection: Monitors for changes in resistance that might indicate wire issues
  • Min/max tracking: Continuously logs peak values for both process and ambient temps
  • Sensor Drift Alert: Warns if dual-sensor readings diverge beyond preset thresholds
  • Hot Backup® (U1 option): Seamlessly switches to backup sensor if primary fails, ensuring uninterrupted output
  • IEC 61508 Safety-Certified: HART‑based units certified up to SIL2 (1oo1 logic) and SIL3 (redundant 1oo2 setup)
  • Independent fail‑safe circuit: In case of processor failure, analog output goes to preset fail‑high or fail‑low state.

Physical & Environmental Design

  • Dual‑compartment rugged housing: Offers robust protection (NEMA4X/IP66/68) against water, dust, wiring noise, and EMI
  • Enclosure materials & entries: Low‑copper aluminium or optional stainless steel, with ½‑14 NPT, M20, PG13.5, or JIS conduit options
  • Operating & storage range: –40°C to +85°C (electronics); 60°C to +120°C (storage) .
  • Stability specs: RTDs maintain ±0.25% or ±0.25°C over 5 years; thermocouples ±0.5% or ±0.5°C
  • Self‑calibrating ADC and robust EMC performance (IEC 61000‑4‑3 up to 30V/m test)

Communication & Local Interface

  • 4‑20mA + HART (Rev5/7) or FOUNDATION Fieldbus (ITK6.0, NE107) with built‑in AI, PID, and advanced diagnostics function blocks
  • Local LCD display: Shows process value and diagnostics graphically; suave configuration and verification onsite

Wiring / Configuration Snapshots

  • Single sensor wiring: Standard RTD or thermocouple hook-up diagrams available for HART and Fieldbus modes.
  • Dual sensor wiring: Supports dual RTDs, dual T/Cs, or mixed RTD+T/C setups—ideal for ΔT, averaging, or redundant measurements
  • Typical response time: ~0.5s for single-sensor mode, ~1s for dual sensors.

Available Options & Configurability

Option Code

Feature

PT

X‑well™ pipe clamp sensor assembly

C1

Factory data: date, tag, custom alarms

C2

Transmitter‑sensor matching

Q4

5‑point calibration certificate

U1/U2

Hot Backup, averaging, drift alert modes

M5

Local LCD display

T1

Transient protection

QT

SIL certification

HR7

HART revision 7

Buy 3144P Harsh Environment 4-20mA Output HART Protocol transmitter Temperature Transmitter at wholesale prices
Send your message to this supplier
 
*From:
*To: Xi'an Xiyi Central Control Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0