Sign In | Join Free | My enlightcorp.com
enlightcorp.com
Products
Search by Category
1-10 Results for

110kv ct ratio tester

from 118 Products

Real Time Monitoring LCD Display 110kV CT Ratio Tester

China Real Time Monitoring LCD Display 110kV CT Ratio Tester on sale
... for online measurement of primary current and secondary current size, conversion ratio, phase difference and polarity judgment of current transformers and transformers below 35kV.The product is composed of primary current clamp (high voltage ......
Wuhan Rising Electric Co., Ltd.

Address: 1st Floor, Block B, Innovation Park, Changzui Science and Technology Park, Sixth High-tech Road, Jiangxia District, Wuhan City, Hubei Province

Automatic Calculation CT Ratio Tester , 600A CT PT Analyser

China Automatic Calculation CT Ratio Tester , 600A CT PT Analyser on sale
CT PT Analyzer Test Equipment MCVT-01C Major Technical Parameters Item Description Power Supply AC220V±10% 50/60HZ Output 0-2500Vrms, 5Arms, 20A (peak value) Big current output 0-600A Excitation accuracy ≤0.2% Secondary winding resistance range/accuracy 0~300Ω / ≤0.2% Secondary burden range/accuracy 5~500VA / 0.2%±0.1VA Phase test (phase angle) Accuracy/ resolution 4min, resolution 0.1min Ratio Error Test Accuracy 0.02% PT ratio......
Zhengzhou Great Electric Co.,Ltd.

Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000

CPT-I Basic Model Low Price CT PT Tester for Transformer Testing

China CPT-I Basic Model Low Price CT PT Tester for Transformer Testing on sale
...CT PT Tester -- Model: CPT-I Introduction: CPT-I CT PT Tester is a special instrument for testing characteristic of CT and PT. CPT-I CT PT Tester can finish CT/PT transformation ratio test, CT/PT polarity test, volt-ampere feature curve drawing and CT error drawing. CPT-I CT PT Tester has large output, high precision,stable performance and automatic testing.​ Features: CT/PT transformation ratio test CT /PT polarity test CT......
Delta Technology (Chongqing) Co., Ltd.

Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010

ZXHQ-A+ CT/ PT Transformer Turns Ratio Tester TTR /Transformer Characteristics Comprehensive Tester

China ZXHQ-A+ CT/ PT Transformer Turns Ratio Tester TTR /Transformer Characteristics Comprehensive Tester on sale
...CT/PT Characteristics Tester It can be used for volt ampere characteristic test of 500kV class 1A current transformer. Product introduction ZXHQ-A+ Series Automatic CT/PT Characteristics Tester is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic,transformation ratio......
Wuhan GDZX Power Equipment Co., Ltd

Address: No.1 Fenghuangyuan Second Road, Jiangxia District, Wuhan City, Hubei Province, China

LB6-110kV CT Current Transformer High Voltage Power Transformer

China LB6-110kV CT Current Transformer High Voltage Power Transformer on sale
... voltage 110kV power system, for energy measurement, current measurement and relay protection purposes. 2.Introduction to Structure LB6-110 type current transformer has an ......
Xi'an Xigao Electricenergy Group Co., Ltd.

Address: Weibei industrial zone, Lintong district, Shanxi. CHINA

CT PT Tester

China CT PT Tester on sale
...CT PT Analyzer HYVA-402V 2. Equipment Description: 1 Turns Ratio, ratio error and phase error test 2 Polarity test for CT 3 Excitation curve and knee voltage measurement in power frequency for CT 4 Error curve test 5 Coil resistance test for CT and PT 6 Secondary burden test for CT 7 Turns ratio......
Wuhan Huaying Electric Power Tech & Science Co.,ltd

Address: 4F,B7,Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Rd, Wuhan,China,430074

0.9-10000 Transformer Turn Ratio Tester 3-phase XHBB128B

China 0.9-10000 Transformer Turn Ratio Tester 3-phase XHBB128B on sale
...Ratio Tester Description In the production process of semi-finished and finished power transformers, before the newly installed transformer is put into operation and according to the preventive test regulations of the Ministry of Electric Power, it is required to test the turns ratio or voltage ratio of the operating transformer, and the transformer turns ratio......
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.

Address: Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an, China

Automatic TTR Transformer Turn Ratio Tester Single Or Three Phase

China Automatic TTR Transformer Turn Ratio Tester Single Or Three Phase on sale
... for three phase transformer. The polarity measurement for single phase transformer or CT/PT Voltage ratio error calculation Current transformer ratio measurement Excitation current measurement in ratio testing Reproduction the AC test voltage from...
Advanced Instruments Co.,Limited

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

0.05 Accuracy CT Transformer Testing Automatic Transformer Ratio Tester

China 0.05 Accuracy CT Transformer Testing Automatic Transformer Ratio Tester on sale
Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ......
Guangzhou GENY Electric Co., Ltd

Address: ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663

Transformer Ratio Tester HYBC-901

China Transformer Ratio Tester HYBC-901 on sale
...single phase transformer or CT/PT 4 Voltage ratio error calculation 5 Current transformer ratio measurement 6 Excitation current measurement in ratio testing 7 Reproduction the AC test voltage from power source to reduce the effects of bad power source 8...
Wuhan Huaying Electric Power Tech & Science Co.,ltd

Address: 4F,Building 7,Optical Valley International Headquarters Industrial Park,No.62,Optical Valley Road,WUHAN,PR.CHINA

Submit your 110kv ct ratio tester inquiry in a minute :
*From:
Your email address is incorrect!
To:

Wuhan Huaying Electric Power Tech & Science Co.,ltd

Products: Transformer Ratio Tester HYBC-901

*Subject:
Your subject must be between 10-255 characters!
*Message:
For the best results, we recommend including the following details:
  • --Self introduction
  • --Required specifications
  • --Inquire about price/MOQ
Your message must be between 20-3,000 characters!
 
Please reply me within 24 hours.
Yes! I would like your verified suppliers matching service!
Yes! If this supplier doesn't contact me in 3 days, I want everychina.com to recommend me more suppliers.
Submit 110kv ct ratio tester inquiry
*From:
Your email address is incorrect!
*Subject:
Your subject must be between 10-255 characters!
*Message:
For the best results, we recommend including the following details:
  • --Self introduction
  • --Required specifications
  • --Inquire about price/MOQ
Your message must be between 20-3,000
Yes! I would like your verified suppliers matching service!
Inquiry Cart 0