Sign In | Join Free | My enlightcorp.com |
|
All ct burden test wholesalers & ct burden test manufacturers come from members. We doesn't provide ct burden test products or service, please contact them directly and verify their companies info carefully.
Total 1046 products from ct burden test Manufactures & Suppliers |
|
![]() |
Brand Name:HNMC Model Number:FY series Place of Origin:China ...CT PT burden box collection FY47 CT Burden Technical Parameters T Rated Current: 1A Power Factor and Rated Burden: COSΦ=0.8:0.625,1.25,2.5,3.75,5,6.25,7.5,10,12.5,15,20,25,30,40,50,60VA COSΦ=1.0: 0.625,1.25,2.5,3.75,5VA Accuracy Class: ±3% Operation Range: (1%-120%). In Test Cable Resistance: 0.06Ω Frequency: 50Hz or 60HZ Operation Model: By Manual Withstand Voltage: 2kV/1min Insulation: Air FY49 CT Burden... |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:AI Model Number:CPT-I Place of Origin:China ...current transformer and voltage transformer at rated burden and working burden in one time test. Fully Automatic CT PT Testing Equipment can automatically evaluate the test results according to the selected standard to determine whether the transformer is |
Advanced Instruments Co.,Limited
Hunan |
![]() |
Model Number:CPT-III Place of Origin:China ... resistance measurement Secondary loop burden measurement Error line curve test for protection CT Transient CT parameters test CT nameplate guess Saturation hysteresis loop curve measurement Tests for voltage transformer: Turns ratio test Ratio error and |
Delta Technology (Chongqing) Co., Ltd.
Chongqing |
![]() |
Brand Name:Fanke High-voltage Model Number:FKFA series Place of Origin:Wuhan ,China CT PT Volt-ampere Characteristics Tester , Multifunctional CT PT Testing I. Product Description: With the increase requirement of relay protection, the test and check of v-c characteristic carve and the 10% error carve of instrument transformer have became... |
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
Hubei |
![]() |
Brand Name:RISING Model Number:RSCTP-1000 Place of Origin:China RSCTP-1000 CT PT Testing Instrument Transformer Analyzer Blue Color Product Description RSCTP-1000 instrument transformer analyzer is a reformed CT and PT testing instrument of new generation researched and developed based on integrated tester for volt-... |
Wuhan Rising Electric Co., Ltd.
Hubei |
![]() |
Brand Name:GFUVE Model Number:GF106 Place of Origin:CHINA ...Test Equipment for CT PT Testing GF106 CT/PT TESTER is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation. FEATURES Steady and transient state characteristic tests of various types of CT... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:HAOMAI Model Number:CTP-200P Place of Origin:China ... IEC61869-3(IEC60044-2), IEEE/ANSI C57.13 etc. test standards. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test labs. Portable CT Analyzer CTP-200P is an all-in-one |
HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD
|
![]() |
Brand Name:KINGSINE Model Number:KT210 Place of Origin:China ...testing; Description ● Adopt 9.7 inch touch screen TFT LCD display with clear and beautiful software interface design, user can operate ... |
Kingsine Electric Automation Co., Ltd.
Guangdong |
![]() |
Brand Name:GENY Model Number:HN-2K01B2 Place of Origin:China Automatic Portable CT On-Site Transformer Test Equipment for Testing of CT’s Radio/Angle Error in Accuracy Class 0.05 Specifications: Current Mutual-inductor On-site Calibration Device The product is mainly used to test one grade to 0.2S grade field ... |
Guangzhou GENY Electric Co., Ltd
|
![]() |
Brand Name:SHENGDI TECHNOLOGY Model Number:HS-6303 Place of Origin:ZHEJIANG.CHINA ... watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing. This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, |
Zhejiang Shengdi Technology Inc.
|
![]() |
Brand Name:GDZX Model Number:ZXHQ-Y Place of Origin:China ZXHQ-Y Transformer Field Calibrator Product introduction ZXHQ-Y is a Multifunctional Current and Voltage Transformer Characteristic Tester designed in accordance with IEC60044-1 / GB1208, IEC60044-2GB1207, IEC60044-6 / GB16847 and C57.13, the instrument... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:YUYANG Model Number:CPT-3 Place of Origin:China CT Tester CT Analyzer CT Testing Equipment Electrical CT Test Set Tester for current transformer: 1.Excitation curve and parameters test 2.Turns ratio test 3. Ratio and phase error test 4. Polarity mark check 5. Coil resistance measurement 6. Secondary loop burden measurement 7. Error line curve test for protection CT 8. Transient CT parameters test 9. CT nameplate guess 10.Saturation hysteresis loop curve measurement Applications of CT... |
DONGGUAN YUYANG INSTRUMENT CO., LTD
Guangdong |
![]() |
Place of Origin:Wuhan Hubei China Brand Name:Huaying Model Number:Huaying Series ...CT PT Analyzer HYVA-402V 2. Equipment Description: 1 Turns Ratio, ratio error and phase error test 2 Polarity test for CT 3 Excitation curve and knee voltage measurement in power frequency for CT 4 Error curve test 5 Coil resistance test for CT and PT 6 Secondary burden test for CT 7 Turns ratio test for PT 8 Polarity test for PT 9 Excitation curve test for PT 10 Coil resistance test... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Place of Origin:Wuhan,Hubei,China Brand Name:Huaying CT PT Analyzer HYVA-405 Tests for Current Transformer: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden measurement 7 Error line curve test for protection CT 8 Transient CT parameters test 9 CT nameplate guess 10 Saturation hysteresis loop curve measurement Tests for Voltage Transformer: 1 Turns ratio test... |
Wuhan Huaying Electric Power Tech & Science Co.,ltd
Hubei |
![]() |
Brand Name:IVY Model Number:anti-tamper ct Place of Origin:Zhejiang ...CT 1.Overview: ● More Optimization On Integrated Unit ● Based On Customized Solutions ● Tailored Ratio, Burden and terminal Output ● Widely used for energy meter, smart grid, generator, EV charger, switching cabinet, medical equipment, circuit protection, electrical machine 2.Specification: Current Ratio Coil Turns Burden... |
IVY METERING CO.,LTD
Shanghai |
![]() |
Brand Name:XG Model Number:LZZW-10 Place of Origin:XIAN,CHINA 1. Technical data OF LZZW-10 Type 10kv 11kv 12kv Outdoor CT Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard ... |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
![]() |
Brand Name:XZH TEST Model Number:XHTX201D Place of Origin:Xi'an, Shaanxi, China ...Test Supply Transformer CT/PT Analyzer Single Phase Excitation Ratio Testing Product Description XHTX201D CT/PT ANALYZER is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, Degauss, 5% and 10% error curves, secondary circuit check, withstand test... |
Xi'an Xu&Hui Electromechanical Technology Co., Ltd.
|
![]() |
Brand Name:HEMEI Model Number:YB42 Place of Origin:China ...electrical cables by clamping on the conductor.This method permits a safer,easy and portable current measurement.An internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output and permits safe opening of the |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |