Brand Name:Daruifuno Model Number:DUC2-DO-S-D Place of Origin:China ...RS485 Interface Dissolved Oxygen Meter For Industry Water Monitoring Common applications for dissolved oxygen meter: 1. Aquaculture: Guarantee the breathing needs of aquatic organisms, real-time monitoring of oxygen content, automatic alarm, automatic oxygenation... |
Suzhou Delfino Environmental Technology Co., Ltd.
Jiangsu |
![]() |
Brand Name:kacise Model Number:KFDO601 Place of Origin:CHINA RS485 Interface Dissolved Oxygen Sensor Anti Interference KFDO601 KFDO601 Online Fluorescence Dissolved Oxygen No Electrolyte Is Required And Will Not Be Polarized No Oxygen Consumption 1.Difference between polarographic and fluorescence measurements of dissolved oxygen 1: Fluorescence method dissolved oxygen... |
Xi'an Kacise Optronics Co.,Ltd.
Shaanxi |
![]() |
Brand Name:Desun Uniwill Model Number:DYS-1 Place of Origin:China ... oxygen in a liquid, typically water. This measurement is crucial in various applications, including environmental monitoring, aquaculture, wastewater treatment, and scientific research. ... |
Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Shaanxi |
![]() |
Brand Name:HiYi Model Number:LH-D800 Place of Origin:China ... user a new use experience.Clear and easy-to-read data interface, excellent anti-interference performance, calibrated point display, accurate measurement, convenient operation, combined with high-brightness backlighting, is your ... |
Beijing HiYi Technology Co., Ltd
Beijing |
![]() |
Brand Name:JUGE Model Number:None Place of Origin:Nanjing, China ...Dissolved Oxygen Analyzer DO Oxygen in Water Controller >>Overview The industrial online dissolved oxygen analyzer is a microprocessor-based water quality online monitoring and control instrument. Equipped with polarographic dissolved oxygen electrodes or fluorescence dissolved oxygen... |
Nanjing Juge Environmental Technology Co., Ltd.
|
![]() |
Brand Name:NANBEI Model Number:JPSL-606L DO Analyzer Place of Origin:China ...Dissolved Oxygen Analyzer , Dissolved Oxygen Controller Brief introduction of DO meter Dissolved oxygen analyzer is the determination of dissolved oxygen in water device, the working principle is oxygen through the diaphragm by the working electrode reduction, resulting in oxygen concentration is proportional to the diffusion current, by measuring this current, the concentration of dissolved oxygen... |
NANBEI INSTRUMENT LIMITED
Henan |
![]() |
Brand Name:Yokogawa Model Number:DO30G-NN-50-10-PN Place of Origin:Japan Yokogawa DO30G/DO70G Measuring Sensor For Dissolved Oxygen Analyzer DO30G-NN-50-10-PN GENERAL The DO30G sensor for dissolved oxygen is designed for use in water treatment plants such as sewage treatment works, effluent activated sludge process, and potable... |
Mengchuan Instrument Co,Ltd.
Zhejiang |
![]() |
Brand Name:HUAKEYI Model Number:HK-318 Place of Origin:China Specification item value Warranty 1 Year Type Dissolved Oxygen Analyzer Customized support OEM Place of Origin China Brand Name HUAKEYI Model Number HK-318 Display 192*64 ... |
Xiangjing (Shanghai) M&E Technology Co., Ltd
Shanghai |
![]() |
Brand Name:CQCY Model Number:70X6 Series Water Quality Analyzer Place of Origin:Shanghai, China 70X6 series of conventional parameters water quality analyzer can analyze pH / 0RP, conductivity / resistivity, dissolved oxygen, turbidity, acid / alkali / salt concentration and other parameters online, which is widely used in pure water preparation, ... |
Chongqing Chuanyi Automation Limited
Shanghai |
![]() |
Brand Name:MC Place of Origin:China Model Number:ZR22G ZR22G Zirconia oxygen analyzer Humidity analyzer RS232/USB communication interface 50Hz-60Hz frequency range *, *::before, *::after {box-sizing: border-box;}* {margin: 0;}html, body {height: 100%;}body {line-height: 1.5;-webkit-font-smoothing: antialiased... |
Yueqing NengYang trading Co., Ltd.
|
![]() |
Brand Name:YuanTe Model Number:YT-95H-O2 Place of Origin:China ... standard keys will be used to realize on-site maintenance. 3. Sandard equipped with three-wire system 4-20mA, RS485 and Inner Relay(24Vdc 100mA) output, external AC relay is optional; 4. Infrared ray controller can remote control alarm ... |
Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Guangdong |
![]() |
Brand Name:GDZX Model Number:ZXSP-9890 Place of Origin:Hubei, China Transformer Oil Dissolved Gas Analyzer Gas Chromatograph with Color LCD Screen Features: 1. With 5.7 inch color LCD screen, intuitive display, easy operation 2. 10/100M adaptive Ethernet communication interface, built-in IP protocol stack, long-distance ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
![]() |
Brand Name:Saving Model Number:DDZY1218 Place of Origin:China ... and systems. One of the standout features of this product is its data storage capabilities. The electric token meter can store and retrieve data, making it easy to track and analyze power consumption patterns over time. This can |
Jiangsu Senwei Electronics Co., Ltd.
Jiangsu |
![]() |
Brand Name:PhyMetrix Model Number:POA200 Place of Origin:CHINA Portable And Lightweight Design , Trace O2 Analyzer , Resolution 0.01ppm User Friendly Interface Once powered on, the POA 200 will automatically adjust it’s charts to the correct range of measurement switching between the different ppm levels. POA 200 is ... |
Beijing york instrument
Beijing |
![]() |
Brand Name:JINHAIHU Model Number:DSC Place of Origin:BEIJING, CHINA Software can be automatic analysis such as polymer melting point, enthalpy change, the glass transition temperature, phase transition temperature, dynamic parameters l Specification: LCD liquid crystal blue backlight display, display information is very... |
Beijing Jinshengxin Testing Machine Co., Ltd.
Beijing |
![]() |
Brand Name:Zetron Model Number:Uvoz-1100 Place of Origin:China Uvoz-300W Dissolved Ozone Concentration Analyzer OVERVIEW This dissolved ozone analyzer with ultraviolet light source automatic system function, can real time according to the reference light data and adjust the brightness of ultraviolet LED light source... |
Beijing Zetron Technology Co., Ltd
Beijing |
![]() |
Brand Name:RAE Model Number:Guard 3 Place of Origin:USA Guard 3 Stationary Toxic Oxygen Detector RS485 Modbus RTU Assure All using advanced sensor technology Wider temperature and environmental factor compensation makes the instrument always reliable and stable Redundant design ensures no "false positives... |
ShenzhenYijiajie Electronic Co., Ltd.
Guangdong |
![]() |
Brand Name:yunyi Model Number:MF5600 Place of Origin:china ...oxygen system MF5600 digital Air gas mass oxygen flow meter Description hospital oxygen system MF5600 digital Air gas mass oxygen flow meter The MF5600 digital air gas mass flow meter are specifically designed to meet the needs of applications that require separation of display and body. For example, the hospital oxygen system small air separation system. The flow meter's standard industrial user interface (RS485... |
Xi'an Yunyi Instrument Co., Ltd
|
![]() |
Brand Name:Wayeal Model Number:WMS1800s Place of Origin:Anhui, China WMS1800s Small Continuous Water Quality Monitoring Equipment Outdoor Product Introduction The outdoor small-scale automatic water quality monitoring system is an outdoor integrated station with a small footprint and easy installation. It can simultaneously... |
Anhui Wanyi Science and Technology Co., Ltd.
Anhui |
![]() |
Brand Name:eyesky Model Number:ES10B11-O2/H Place of Origin:china ...RS485 Oxygen Gas Detector For Confined Space Product Details Parameter Technical indicators O2 measurement range 0-30%/0-100% Measurement method Electrochemical probe Response time Usually less than 15 seconds Warranty period Host warranty for 2 years, gas probe warranty for 1 year O2 measurement accuracy ≤ ± 3% Interface form Digital(RS485... |
Shenzhen Eyesky&Safewill Technology Co.,Ltd.
Guangdong |